Data Center Acoustics

Data Center Acoustics

Data Center Acoustics

Data Center Perimeter Acoustics

The Low-End HUM Requires High-End Acoustics

Every modern data center generates a constant low-frequency drone — the relentless HUM of cooling fans, compressors, pumps, transformers, and standby generators. It travels farthest, penetrates walls, and reaches the bedrooms of the neighbors. It triggers community complaints, halts approvals, and exposes owners and operators to nuisance lawsuits and costly retrofits.

Fences and reflective walls cannot stop it. Walls of Troy can — a 22’+ tall absorptive and isolation barrier rated STC 53 / NRC 0.90, Riverbank Labs certified, and proven on American highways since 1993.

Performance at a Glance

53
STC Rating
0.90
NRC Absorption
22’+
Wall Height
0 / 0
UL 723 Flame / Smoke
Highway with green sound barrier

For Contractors & Developers

Specify Troy on day one and you build a campus that passes acoustic compliance at every octave band — no costly retrofits, no permit-revision cycles, no schedule-killing change orders.

Suburban residential neighborhood

For City Councils & Planners

Approving a data center is a long-term commitment to the residents around it. Conditioning approval on Walls of Troy — STC 53, NRC 0.90, 22’+ tall — is the most defensible vote you can take.

Industrial facility

For Homeowners & Neighbors

The reason you can hear a data center a mile away is the low-frequency HUM no ordinary wall stops. Walls of Troy absorbs and blocks that frequency band — restoring the quiet you bought your home for.

Certifications & Standards

Certified Performance Across the Frequency Spectrum

34 dB

34 dB at 31.5 Hz

Transmission loss at the deepest end of the data center HUM band, where ordinary walls fail.

64 dB

64 dB at 5 kHz

Transmission loss climbs to 64 dB at high frequencies. STC 53 per Riverbank Labs test RAL-TL26-262.

NRC

NRC 0.90

The absorptive face soaks up sound instead of reflecting it back toward the community. Riverbank Labs test RAL-A26-364.

UL

UL 723 Class A

Zero (0) flame spread and zero (0) smoke developed. Absorptive panels are machined and painted for long life and no maintenance.

Applications

Where We’re Used

Exterior Perimeter Walls

Exterior Perimeter Walls

22’+ absorptive and isolation walls that stop the HUM at the property line.

Chiller & Cooling Yards

Chiller & Cooling Yards

Contain the 24/7 fan and compressor drone — the main low-frequency source.

Generator & Equipment Yards

Generator & Equipment Yards

Shield neighbors from backup generator test runs and transformer hum.

Interior Ceiling Systems

Interior Ceiling Systems

CAC 38 · NRC 1.0 ceiling systems for interior equipment and support spaces.

New Campus Construction

New Campus Construction

Design acoustics in before permitting to avoid denials, lawsuits, and retrofits.

Retrofits & Expansions

Retrofits & Expansions

Bring existing campuses into compliance as noise rules tighten.

Quiet Is a Liability Question

Communities sue. Regulators fine. Property values fall. Walls of Troy absorbs the HUM at the property line — before it ever reaches a neighbor. Plan the wall before the permit hearing.